Dranchuk correlation
From wiki.pengtools.com
Revision as of 05:43, 25 April 2017 by Gprotsykov (talk | contribs)
Brief
Liquid loading is a phenomenon when the gas phase does't provide sufficient transport energy to lift the liquids out of the well.
In 1969 Turner et al. published an empirical correlation defining the Liquid loading gas velocity.
Math & Physics
A1 = 0.3265 A¬ = –1.0700 A3 = –0.5339 A4 = 0.01569 A5 = –0.05165 A6 = 0.5475 A7 = –0.7361 A8 = 0.1844 A9 = 0.1056 A10 = 0.6134 A11 = 0.7210
The minimum gas rate to remove the liquid equation:
Discussion
To avoid the Liquid loading the gas velocity should be above the Liquid loading velocity.
The higher the gas rate the higher the gas velocity.
The lower the wellhead flowing pressure the higher the gas rate.
The bigger the tubing ID the higher the gas rate.
In case when the gas rate is limited by the Reservoir deliverability smaller tubing ID will increase the gas velocity.
Nomenclature
- = flow area, ft^2
- = flowing wellhead pressure, psia
- = gas rate, MMscf/d
- = gas density, lbm/ft3
- = liquid density, lbm/ft3
- = surface tension, dyne/cm (ref values: 60 - water, 20 - condensate) [1]
- = flowing temperature, °R
- = gas velocity, ft/sec
- = gas compressibility factor at flowing P & T, dimensionless
References
- ↑ 1.0 1.1 Turner, R. G.; Hubbard, A. E.; Dukler (Nov 1969). "Analysis and Prediction of Minimum Flow Rate for the Continuous Removal of Liquids from Gas Wells". Journal of Petroleum Technology (SPE-2198-PA): 1475–1482.