Difference between revisions of "3 Phase IPR"
(→Math and Physics) |
(→Nomenclature) |
||
Line 40: | Line 40: | ||
== Nomenclature == | == Nomenclature == | ||
− | :<math> | + | :<math> VF </math> = volume factor, bbl/stb |
− | :<math> | + | :<math> WCUT</math> = water cut, fraction |
− | :<math> | + | :<math> B</math> = volume factor, dimensionless |
− | :<math> | + | :<math> GLR</math> = gas liquid ratio, ? scf / stb |
− | :<math> | + | :<math> R</math> = solution gas ration, scf / stb |
− | :<math> q </math> = flowing rate, stb/d | + | :<math> V </math> = total volume of produced fluid rate (inducing gas), bbl/d |
+ | :<math> q </math> = flowing rate, stb/d | ||
+ | |||
===Subscripts=== | ===Subscripts=== | ||
− | : | + | :w = water<BR/> |
− | |||
:o = oil<BR/> | :o = oil<BR/> | ||
− | : | + | :sc = standard conditions |
:t = total<BR/> | :t = total<BR/> | ||
− | |||
− | |||
== References == | == References == |
Revision as of 07:38, 17 April 2019
Contents
Three-phase Inflow Performance Relationship
3 Phase IPR is an IPR curve calculated on the basis of total barrels of produced fluid, including gas.
3 Phase IPR curve is used in Pump Design software for pump sizing.
Math and Physics
The volume of 1 stb of liquid plus associated gas at any pressure and temperature is given by[1]:
The total volume of produced fluid rate (liquid plus gas) at any conditions of pressure and temperature:
is calculated as usual using:
- Vogel's IPR equation
- Composite IPR equation
3 Phase IPR calculation example
Following the well #1 example given by Brown[1]on Figure 5.8, page 191:
Given:
- = 2550 psi
- = 2100 psi
Test data:
- = 2300 psi
- = 500 b/d
Calculate:
Determine the 3 Phase IPR curves for Fw=0, 0.25, 0.5, 0.75, and 1.
Solution:
The problem was run through PQplot software for different values of watercut.
Result 3 Phase IPR curves are shown on Fig.1. Points indicate results obtained by Brown [1].
The PQplot model from this example is available online by the following link: 3 Phase IPR calculation example
Nomenclature
- = volume factor, bbl/stb
- = water cut, fraction
- = volume factor, dimensionless
- = gas liquid ratio, ? scf / stb
- = solution gas ration, scf / stb
- = total volume of produced fluid rate (inducing gas), bbl/d
- = flowing rate, stb/d
Subscripts
- w = water
- o = oil
- sc = standard conditions
- t = total