Difference between revisions of "3 Phase IPR"
(→Math and Physics) |
(→Math and Physics) |
||
Line 16: | Line 16: | ||
:<math> q_{t_{sc}} </math> is calculated as usual using: | :<math> q_{t_{sc}} </math> is calculated as usual using: | ||
− | *[[Vogel's IPR]] | + | *[[Vogel's IPR]] equation |
− | *[[Composite IPR]] | + | *[[Composite IPR]] equation |
==[[3 Phase IPR]] calculation example== | ==[[3 Phase IPR]] calculation example== |
Revision as of 07:14, 17 April 2019
Contents
Three-phase Inflow Performance Relationship
3 Phase IPR is an IPR curve calculated on the basis of total barrels of produced fluid, including gas.
3 Phase IPR curve is used in Pump Design software for pump sizing.
Math and Physics
The volume of 1 stb of liquid plus associated gas (volume factor) at any pressure and temperature is given by[1]:
The total volume of produced fluid rate (liquid plus gas) at any conditions of pressure and temperature:
- is calculated as usual using:
- Vogel's IPR equation
- Composite IPR equation
3 Phase IPR calculation example
Following the example problem #21, page 33 [1]:
Given:
- = 2550 psi
- = 2100 psi
Test data:
- = 2300 psi
- = 500 b/d
Calculate:
Determine the 3 Phase IPR curves for Fw=0, 0.25, 0.5, 0.75, and 1.
Solution:
The problem was run through PQplot software for different values of watercut.
Result 3 Phase IPR curves are shown on Fig.1. Points indicate results obtained by Brown [1].
The PQplot model from this example is available online by the following link: 3 Phase IPR calculation example
Nomenclature
- = calculation variables
- = oil fraction, fraction
- = water fraction, fraction
- = productivity index, stb/d/psia
- = pressure, psia
- = flowing rate, stb/d
Subscripts
- b = at bubble point
- max = maximum
- o = oil
- r = reservoir
- t = total
- wf = well flowing bottomhole pressure
- wfG = well flowing bottomhole pressure at point G