Difference between revisions of "6/π stimulated well potential"
From wiki.pengtools.com
(→Math & Physics) |
|||
Line 22: | Line 22: | ||
:<math> V =y_e*h*x_e/2*\phi</math> | :<math> V =y_e*h*x_e/2*\phi</math> | ||
− | :<math>c=\frac{1}{ | + | :<math>c=-\frac{1}{V} \frac{dV}{dP}</math> |
From [[Darcy's law]]: | From [[Darcy's law]]: |
Revision as of 09:42, 12 September 2018
Brief
6/π is the maximum possible stimulation potential for pseudo steady state linear flow in a square well spacing.
Math & Physics
Pseudo steady state flow boundary conditions:
From Diffusivity Equation:
From Material Balance:
From Darcy's law:
- ( 2 )
Diff eq
From Mass conservation:
- ( 1 )
From Darcy's law:
- ( 2 )
( 2 ) →( 1 ):
- ( 3 )
- ( 4 )
- ( 5 )
( 5 ) -> ( 4 ):
- ( 6 )
- ( 7 )
Assumption that viscosity is constant cancels out first term in left hand side of (7):
- ( 8 )
- ( 9 )
( 9 ) -> ( 8 ):
- ( 10 )
Term in (10) is second order of magnitude low and can be cancelled out, which yields:
- ( 11 )
See also
optiFrac
fracDesign
Production Potential
Nomenclature
- = cross-sectional area, cm2
- = thickness, m
- = permeability, d
- = pressure, atm
- = initial pressure, atm
- = average pressure, atm
- = flow rate, cm3/sec
- = length, m
- = drinage area length, m
- = drinage area width, m
Greek symbols
- = oil viscosity, cp