VRR

From wiki.pengtools.com
Revision as of 17:00, 22 March 2022 by MishaT (talk | contribs) (Created page with "__TOC__ ==Brief== VRR stands for voidage replacement ratio. It is the ratio of injected fluid to produced fluid at the reservoir conditions. ===Equation=== :<math> HCPV...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Brief

VRR stands for voidage replacement ratio. It is the ratio of injected fluid to produced fluid at the reservoir conditions.

Equation

 HCPV = A * h * \phi * S_o

where

 A = Area, m2
 h = Net pay, oil saturated thickness, m
 HCPV = Hydrocarbon pore volume, m3
 \phi = Porosity, fraction
 S_o = Oil saturation, fraction

Related definitions

Pore volume:

 PV = A * h * \phi

Movable pore volume:

 MOPV = A * h * \phi *(1-S_{wc}-S_{orw})

where

 S_{wc} = Connate water saturation, fraction
 S_{orw} = Residual oil saturation, fraction