From [[Darcy's law]] for an unfractured injection well located in the center of a circular drainage area, the injection rate in pseudo-steady state is: | From [[Darcy's law]] for an unfractured injection well located in the center of a circular drainage area, the injection rate in pseudo-steady state is: | ||
| − | :<math> {q_{inj}} = \frac{kh}{141.2 B \mu} \times | + | :<math> {q_{inj}} = \frac{kh}{141.2 B \mu} \times (P_{wf} - \bar{P}) \times J_D </math> |
== Nomenclature == | == Nomenclature == | ||
Revision as of 15:33, 27 August 2026
Contents
Brief
Hall Plot is the engineering technique to analyze performance of injection wells published in 1963 by Howard Hall [1].
Hall Plot is applied to determine the change in the Injectivity index of the wells.
Hall Plot uses readily available Well flowing data: injection rate and wellhead pressures.
The interpretation technique is fitting the data points with the straight lines to estimate injectivity change.
Math & Physics
From Darcy's law for an unfractured injection well located in the center of a circular drainage area, the injection rate in pseudo-steady state is:
Nomenclature
See Also
- ↑ Hall, H.N. (1963). "How To Analyze Waterflood Injection Well Performance". World Oil.