Difference between revisions of "Relative Permeability"
(→Example) |
|||
Line 38: | Line 38: | ||
Same core at 70% water and 30% oil and qw=0.332 cc/sec and qo=0.0184 cc/sec: | Same core at 70% water and 30% oil and qw=0.332 cc/sec and qo=0.0184 cc/sec: | ||
− | :<math> k_w = \frac{0.332*1*1*3}{2*2} = 0.249 D = 249 mD </math> | + | :<math> k_w(S_w=0.7)= \frac{0.332*1*1*3}{2*2} = 0.249 D = 249 mD </math> |
− | :<math> k_o = \frac{0.0184*1.2*3*3}{2*2} = 0.049 D = 50 mD </math> | + | :<math> k_o(S_w=0.7)= \frac{0.0184*1.2*3*3}{2*2} = 0.049 D = 50 mD </math> |
Revision as of 16:46, 30 March 2022
Brief
Relative Permeability is the ratio of the effective permeability to base oil permeability measured at connate water saturation[1].
where
- Oil relative permeability, fraction
- Water relative permeability, fraction
- Effective water permeability, mD
- Effective water permeability, mD
- Effective oil permeability at irreducible oil saturation, mD
- Connate water saturation, fraction
Related definitions
Effective permeability - oil, water, gas phase permeability when more than one phase is present. Depends on fluids saturations.
Absolute permeability - permeability of the core sample when saturated with one liquid. Independent of fluid. Dependent on pore throat sizes.
Example
Determine the Relative Permeability using the following data[1]:
Core dimensions: A=2 cm2, L=3 cm. PVT: water viscosity = 1 cP, oil viscosity = 3 cP, Bw=1 cc/cc, Bo=1.2 cc/cc.
Core is at 100% water and qw=0.553 cc/sec:
Using Darcy's law:
Same core at 100% oil and qo=0.154 cc/sec:
Same core at 70% water and 30% oil and qw=0.332 cc/sec and qo=0.0184 cc/sec:
In this case the mobility of water is 15 times higher than the mobility of water.
See Also
References
- ↑ 1.0 1.1 Wolcott, Don (2009). Applied Waterflood Field Development. Houston: Energy Tribune Publishing Inc.