Difference between revisions of "VRR"

From wiki.pengtools.com
Jump to: navigation, search
Line 8: Line 8:
  
 
===Equation===
 
===Equation===
:<math> VRR = \frac{Injected\ reservoir\ volumes}{Produced\ reservoir\ volumes} = \frac{W_i B_{wi} + I_g B_{gi}}{N_p B_o + W_p B_{wp} + B_g(GOR-R_s)N_p}</math>
+
:<math> VRR = \frac{Injected\ reservoir\ volumes}{Produced\ reservoir\ volumes} = \frac{W_i B_{wi} + G_{gi} B_{gi}}{N_p B_o + W_p B_{wp} + B_g(GOR-R_s)N_p}</math>
  
 
where
 
where
Line 18: Line 18:
 
:<math> B_o </math> = Oil formation volume factor, m3/m3
 
:<math> B_o </math> = Oil formation volume factor, m3/m3
 
:<math> GOR </math> = Produced gas oil ratio, m3/m3
 
:<math> GOR </math> = Produced gas oil ratio, m3/m3
:<math> I_g </math> = Injected gas volume, m3
+
:<math> G_{gi} </math> = Injected gas volume, m3
 
:<math> N_p </math> = Oil produced, m3
 
:<math> N_p </math> = Oil produced, m3
 
:<math> R_s </math> = Solution gas oil ratio, m3/m3
 
:<math> R_s </math> = Solution gas oil ratio, m3/m3
Line 32: Line 32:
 
*[[Block]]
 
*[[Block]]
 
*[[Mature Water Flood Analysis]]
 
*[[Mature Water Flood Analysis]]
 +
*[[Oil Material Balance]]
  
 
[[Category:E&P Portal]]
 
[[Category:E&P Portal]]

Revision as of 14:17, 23 March 2022

Brief

VRR stands for voidage replacement ratio. It is the ratio of injected fluid to produced fluid at the reservoir conditions.

VRR is calculated with the current rates and on the cumulative basis VRRcum.

Equation

 VRR = \frac{Injected\ reservoir\ volumes}{Produced\ reservoir\ volumes} = \frac{W_i B_{wi} + G_{gi} B_{gi}}{N_p B_o + W_p B_{wp} + B_g(GOR-R_s)N_p}

where

 B_{g} = Gas formation volume factor, m3/m3
 B_{gi} = Injected gas formation volume factor, m3/m3
 B_{wi} = Injected water formation volume factor, m3/m3
 B_{wp} = Produced water formation volume factor, m3/m3
 B_o = Oil formation volume factor, m3/m3
 GOR = Produced gas oil ratio, m3/m3
 G_{gi} = Injected gas volume, m3
 N_p = Oil produced, m3
 R_s = Solution gas oil ratio, m3/m3
 VRR = Voidage replacement ratio, fraction
 W_i = Water injected, m3
 W_p = Water produced, m3

See Also