Difference between revisions of "VRR"
From wiki.pengtools.com
(→Equation) |
|||
Line 6: | Line 6: | ||
===Equation=== | ===Equation=== | ||
− | :<math> VRR = \frac{Injected reservoir volumes}{Produced reservoir volumes} = \frac{W_i B_{wi} + W_g B_{gi}}{N_p B_o + W_p B_{wp} + B_g(GOR-R_s)N_p}</math> | + | :<math> VRR = \frac{Injected\ reservoir\ volumes}{Produced reservoir volumes} = \frac{W_i B_{wi} + W_g B_{gi}}{N_p B_o + W_p B_{wp} + B_g(GOR-R_s)N_p}</math> |
where | where |
Revision as of 14:03, 23 March 2022
Brief
VRR stands for voidage replacement ratio. It is the ratio of injected fluid to produced fluid at the reservoir conditions.
Equation
where
- = Area, m2
- = Net pay, oil saturated thickness, m
- = Hydrocarbon pore volume, m3
- = Porosity, fraction
- = Oil saturation, fraction
Related definitions
Pore volume:
Movable pore volume:
where
- = Connate water saturation, fraction
- = Residual oil saturation, fraction
See Also