Difference between revisions of "Hagedorn and Brown correlation"

From wiki.pengtools.com
Jump to: navigation, search
Line 5: Line 5:
 
It doesn't distinguish between the flow regimes.
 
It doesn't distinguish between the flow regimes.
  
The heart of the Hagedorn-Brown method is a correlation for liquid holdup.
+
The heart of the [[Hagedorn and Brown]] method is a correlation for liquid holdup.
  
 
== Workflow ==
 
== Workflow ==

Revision as of 14:44, 14 March 2017

Info

Hagedorn and Brown is an empirical two-phase flow correlation published in 1965.

It doesn't distinguish between the flow regimes.

The heart of the Hagedorn and Brown method is a correlation for liquid holdup.

Workflow

 144 \frac{\Delta p}{\Delta h} = \bar \rho_m + \frac{f q_L^2 M^2}{2.9652 \times 10^{11} D^5 \bar \rho_m} + \bar \rho_m \frac{\Delta{(\frac{v_m^2}{2g_c}})}{\Delta h}
 \bar \rho_m = \bar \rho_L H_L + \bar \rho_g (1 - H_L)

Block Diagram

References