Hagedorn and Brown correlation
From wiki.pengtools.com
												
																
				Brief
Hagedorn and Brown is an empirical two-phase flow correlation published in 1965.
It doesn't distinguish between the flow regimes.
The heart of the Hagedorn and Brown method is a correlation for the liquid holdup : .
.
Math & Physics
Following the law of conservation of energy the basic steady state flow equation is:
where
Colebrook–White equation for the Darcy's friction factor:
Reynolds two phase number:
Workflow
corr p1
corr p2









![N_L = 0.15726\ \mu_L \sqrt[4]{\frac{1}{\rho_L \sigma_L^3}}](/images/math/b/2/0/b207fe79b4a4ee53d466e182791ca737.png)



![N_{LV} = 1.938 v_{SL} \sqrt[4]{\frac{\rho_L}{\sigma}}](/images/math/a/2/8/a28bad36b56c7e5e27247199085135b9.png)
![N_{GV} = 1.938 v_{SG} \sqrt[4]{\frac{\rho_L}{\sigma}}](/images/math/e/7/3/e731bf45526c59f675036c93fee286a8.png)