Hagedorn and Brown correlation
From wiki.pengtools.com
Brief
Hagedorn and Brown is an empirical two-phase flow correlation published in 1965.
It doesn't distinguish between the flow regimes.
The heart of the Hagedorn and Brown method is a correlation for the liquid holdup :
.
Math & Physics
Following the law of conservation of energy the basic steady state flow equation is:
where
Colebrook–White equation for the Darcy's friction factor:
Reynolds two phase number:









![N_L = 0.15726\ \mu_L sqrt[4]{(\frac{1}{\rho_L \sigma_L^3}}](/images/math/7/c/0/7c02fdc1f0682abd3067122e191007b5.png)