Hagedorn and Brown correlation
From wiki.pengtools.com
Brief
Hagedorn and Brown is an empirical two-phase flow correlation published in 1965.
It doesn't distinguish between the flow regimes.
The heart of the Hagedorn and Brown method is a correlation for the liquid holdup :.
Math & Physics
Following the law of conservation of energy the basic steady state flow equation is:
where
Colebrook–White equation for the Darcy's friction factor:
Reynolds two phase number:
Workflow
- Failed to parse (syntax error): N_L = 0.15726\ \mu_L \left \frac{1}{\rho_L \sigma_L^3} \right^(0.25)