Contents
Brief
Beggs and Brill is an empirical two-phase flow correlation published in 1972 [1].
It distinguish between 4 flow regimes.
Beggs and Brill is the default VLP correlation in sPipe.
Math & Physics
Fluid flow energy balance
where
Friction factor
No slip Reynolds two phase number:
Colebrook–White [3] equation for the Darcy's friction factor:
Corrected two phase friction factor:
where
and
with constraint:
Discussion
Why Beggs and Brill?
The best correlation for the horizontal flow.— pengtools.com
Flow Diagram
Workflow HL
Determine the flow pattern:
Calculate
- with the constraint
[2]
C Uphill:
C Downhill:
- ALL:
[2]
- with the restriction
[2]
Finally:
- SEGREGATED, INTERMITTENT, DISTRIBUTED:
- TRANSITION:
where:
Modifications
1. Force approach gas at low CL. If CL<0.001 Then f'=f.
2. Force approach to single phase fluid. If HL>1 Then HL=1.
3. Use calculated water density instead of the constant value of 62.4 lbm/ft3.
Nomenclature
= flow area, ft2
= correlation group, dimensionless
= formation factor, bbl/stb
= coefficient for liquid viscosity number, dimensionless
= pipe diameter, ft
= depth, ft
= correlation group, dimensionless
= liquid holdup factor, dimensionless
= friction factor, dimensionless
= gas-liquid ratio, scf/bbl
= total mass of oil, water and gas associated with 1 bbl of liquid flowing into and out of the flow string, lbm/bbl
= pipe diameter number, dimensionless
= gas velocity number, dimensionless
= liquid viscosity number, dimensionless
= liquid velocity number, dimensionless
= pressure, psia
= conversion constant equal to 32.174049, lbmft / lbfsec2
= total liquid production rate, bbl/d
= Reynolds number, dimensionless
= solution gas-oil ratio, scf/stb
= specific gravity, dimensionless
= temperature, °R or °K, follow the subscript
= velocity, ft/sec
= water-oil ratio, bbl/bbl
= gas compressibility factor, dimensionless
Greek symbols
= absolute roughness, ft
= viscosity, cp
= density, lbm/ft3
= integrated average density at flowing conditions, lbm/ft2
= surface tension of liquid-air interface, dynes/cm (ref. values: 72 - water, 35 - oil)
= secondary correlation factor, dimensionless
Subscripts
g = gas
K = °K
L = liquid
m = gas/liquid mixture
o = oil
R = °R
SL = superficial liquid
SG = superficial gas
w = water
References
- ↑ 1.0 1.1 1.2 1.3 Beggs, H. D.; Brill, J. P. (May 1973). "A Study of Two-Phase Flow in Inclined Pipes"
. Journal of Petroleum Technology. AIME. 255 (SPE-4007-PA).
- ↑ 2.00 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.08 2.09 2.10 2.11 2.12 2.13 2.14 2.15 2.16 2.17 2.18 2.19 2.20 2.21 2.22 2.23 2.24 2.25 2.26 Brill, H. D.; Beggs, J. P. (January, 1991). Two-Phase Flow In Pipes (6 ed.). Oklahoma: U. of Tulsa Tulsa. ISBN 978-0-13-703158-0. Check date values in:
|date=
(help) - ↑ Colebrook, C. F. (1938–1939). "Turbulent Flow in Pipes, With Particular Reference to the Transition Region Between the Smooth and Rough Pipe Laws"
. Journal of the Institution of Civil Engineers. London, England. 11: 133–156.
- ↑ Moody, L. F. (1944). "Friction factors for pipe flow"
. Transactions of the ASME. 66 (8): 671–684.
- ↑ 5.0 5.1 5.2 5.3 5.4 5.5 5.6 Lyons, W.C. (1996). Standard handbook of petroleum and natural gas engineering. 2. Houston, TX: Gulf Professional Publishing. ISBN 0-88415-643-5.