Validation uses the SCENARIO_CALC_PVT rule set.
+
Ranges below are expressed in internal units (the units the validator sees), with common METRIC/FIELD equivalents for convenience.
  
 
{| class="wikitable"
 
{| class="wikitable"

Revision as of 10:27, 15 July 2026

PVT API

The PVT calculator models reservoir fluid properties (oil, gas, water) over a pressure range using various correlations, and returns property curves (plots), single‑point reservoir‑condition values (solution), and a stepped property table (results) available in PVT calculator of the pengtools.

Endpoints

All endpoints require the Authorization: Bearer <api_key> header and are subject to rate limiting. The response envelope is always { "success": <bool>, "data": <payload> }

Method Path Purpose
POST /pvt-calculator/calc Synchronous — compute and return the result in the same request
POST /pvt-calculator/calc-async Asynchronous — enqueue a job, return a {token}
GET /pvt-calculator/{token}/status Job status and progress
GET /pvt-calculator/{token}/output-data Job result (same shape as the sync data)
GET /pvt-calculator/{token}/input-data The input the job was created with
POST /pvt-calculator/{token}/start Reset and re-run the job
POST /pvt-calculator/{token}/stop Stop a running job
DELETE /pvt-calculator/{token} Delete the job

Use /calc (synchronous) for normal interactive requests — a single PVT model computes in well under a second and the result comes back in the HTTP response.

Use /calc-async only for batch/heavy workloads where you would rather not hold an open HTTP connection. The async path enqueues an api_task row that is picked up by the CalcDaemon worker; you then poll status and fetch output-data. The async job runs the same calculatePvt() code as the sync endpoint, so the result is identical for identical input.

Synchronous request

POST /pvt-calculator/calc

The request body is a JSON object containing PVT calculator attributes plus two optional unit-control keys:

{
 "unit_system": "RU",
 "defaultFluidType": "OIL",
 "maximumPressure": 300,
 "reservoirPressure": 300,
 "temperature": 90,
 "pBubbleInitial": 200,
 "rsbInitial": 60,
 "isRsbUsedForPb": true,
 "sgOil": 0.85,
 "sgGas": 0.75,
 "sgWater": 1.0
}

On success the endpoint returns HTTP 200 with:

{ "success": true, "data": { "plots": {},"solution": {}, "results": {}  } }

Where data carries:

  • plots — property curves
  • solution — single-point reservoir-condition values
  • results — stepped property table

Units

Input field names (e.g., maximumPressure, temperature) carry no unit. The unit system determines how values are interpreted.

unit_system 

a shortcut that applies a whole preset of units. Accepted values (case‑insensitive):

  • METRIC - Metric system
  • FIELD - Field system

Example:

{
 "unit_system": "METRIC",
 "maximumPressure": 300,
 "temperature": 90
}

Attribute units

Field METRIC FIELD
maximumPressure ATM PSIA
minimumPressure ATM PSIA
reservoirPressure ATM PSIA
pBubbleInitial ATM PSIA
temperature CELSIUS FAHRENHEIT
rsbInitial M3_PER_M3 SCF_PER_BBL
sgOil SPECIFIC_GRAVITY API
sgGas SPECIFIC_GRAVITY SPECIFIC_GRAVITY
sgWater SPECIFIC_GRAVITY SPECIFIC_GRAVITY

Input parameter specification

Ranges below are expressed in internal units (the units the validator sees), with common METRIC/FIELD equivalents for convenience.

Field Required Notes
defaultFluidType yes OIL or GAS. Selects the primary fluid path. WATER is only valid inside forFluid.
maximumPressure yes Upper bound of the pressure sweep.
minimumPressure no (default 14.6) Lower bound of the sweep; must be ≤ maximumPressure.
reservoirPressure yes Reservoir-condition pressure for solution.
temperature yes Reservoir temperature.
pBubbleInitial yes Initial bubble point. See isRsbUsedForPb.
rsbInitial yes (when OIL) Solution GOR at bubble point.
sgOil yes Oil specific gravity. US system accepts API.
sgGas yes Gas specific gravity (air = 1).
sgWater yes Water specific gravity.
isRsbUsedForPb no (default false) true: derive bubble point from rsbInitial. false: derive GOR from pBubbleInitial.
forFluid no (default all) Subset of OIL, GAS, WATER. Which fluids to compute.
needPlots no (default true) Include the plots block.
needSolution no (default true) Include the solution block.
needResults no (default true) Include the results block.

Notes

For an oil model, both pBubbleInitial and rsbInitial are required; isRsbUsedForPb decides which one is the input and which is derived.