Difference between revisions of "Liquid loading"
From wiki.pengtools.com
Line 5: | Line 5: | ||
The minimum gas velocity to remove the liquid equation: | The minimum gas velocity to remove the liquid equation: | ||
− | :<math> v_g = 1.593 \sigma^{1/4} \frac{{\rho_L-\rho_g}^{1/4}}{\rho_g^{1/2}}</math> | + | :<math> v_g = 1.593 \sigma^{1/4} \frac{({\rho_L-\rho_g})^{1/4}}{\rho_g^{1/2}}</math> |
[[Category:PEngTools]] | [[Category:PEngTools]] | ||
[[Category:pqPlot]] | [[Category:pqPlot]] |
Revision as of 11:56, 15 March 2017
Liquid loading is a phemonenon when the gas phase does't provide sufficient transport energy to lift the liquids out of the well.
The minimum gas velocity to remove the liquid equation: